JIS Z 4333 X線,γ線及びβ線用線量当量(率)サーベイメータ|日本産業規格|最新情報 更新 改正制定
JIS Z 4333 X線,γ線とβ線用線量当量(率)サーベイメータの日本産業規格 JISZ4333の一覧・基本・名称・用語・知識・JIS最新改正更新情報に関して解説!
JIS Z4333:2014の規格は,放射線サーベイを目的として,X線,γ線及びβ線の周辺線量当量(率)H*(10),H*(10)及び/又は方向性線量当量(率)H'(0.07),H'(0.07)を測定する携帯形の線量(率)計及び警報付き線量(率)計について規定。
ページコンテンツ
- 1 X線,γ線とβ線用線量当量(率)サーベイメータ 規格 一覧表
- 2 最新 JIS Z4333 規格の詳細 更新日 情報
- 3 JIS Z4333:2014 目次
- 4 適用範囲 [1]
- 5 引用規格 [2]
- 6 用語と定義 [3]
- 6.1 変動係数,ν(coefficient of variation) [3.1]
- 6.2 基準レスポンス,R0(reference response) [3.3]
- 6.3 相対レスポンス,r(relative response) [3.4]
- 6.4 有効測定範囲(effective range of measurement) [3.5]
- 6.5 有効測定範囲の下限値,H0,H0(lower limit of effective range of measurement) [3.6]
- 6.6 指示値,G(indicated value) [3.7]
- 6.7 基準の向き(reference orientation) [3.8]
- 6.8 基準点(reference point) [3.9]
- 6.9 取決め真値,Ht,Ht(conventional true value) [3.10]
- 6.10 相対拡張不確かさ,urel(relative expanded uncertainty) [3.11]
- 6.11 定格範囲(rated range) [3.12]
- 6.12 最小定格範囲(minimal rated range) [3.13]
- 6.13 周辺線量当量,H*(10)(ambient dose equivalent) [3.14]
- 6.14 方向性線量当量,H'(0.07,α)(directional dose equivalent) [3.15]
- 7 性能 [4]
- 8 X線 関連 主なJIS規格 一覧
X線,γ線とβ線用線量当量(率)サーベイメータ 規格 一覧表

X線,γ線及びβ線用線量当量(率)サーベイメータの一覧
最新 JIS Z4333 規格の詳細 更新日 情報
JIS Z 4333:2014の最新の詳細や改正,更新日の情報!
JIS 改正 最新情報
| JIS規格番号 | JIS Z4333 | JIS改正 最新・更新日 | 2014年03月20日 |
|---|---|---|---|
| 規格名称 | X線,γ線とβ線用線量当量(率)サーベイメータ | ||
| 英語訳 | Portable ambient and/or directional dose equivalent (rate) meters and/or monitors for X, gamma and beta radiation | ||
| 対応国際規格 ISO | |||
| 対応国際規格 IEC | IEC 60846-1:2009(MOD) | ||
| 主務大臣 | 経済産業 | 制定 年月日 | 1990年01月01日 |
| 略語・記号 | No | JIS Z4333:2014 | |
| ICS | 17.240 | JISハンドブック | 非破壊検査:2019 |
| 改訂 履歴 | 1990-01-01 (制定),1997-06-20 (確認),2001-03-20 (改正),2006-03-25 (改正),2010-10-01 (確認),2014-03-20 (改正),2018-10-22 (確認) | ||
JIS規格「日本工業規格」は、2019年7月1日の法改正により名称が「日本産業規格」に変わりました。
JIS Z4333:2014 目次
- 序文
- 1 適用範囲
- 2 引用規格
- 3 用語と定義
- 4 性能
- 4.1 直線性
- 4.2 変動係数
- 4.3 エネルギー・方向特性
- 4.4 線量測定における線量率特性
- 4.5 応答時間
- 4.6 オーバロード特性
- 4.7 ドリフト
- 4.8 ウォームアップ時間
- 4.9 β線による影響
- 4.10 警報設定精度
- 4.11 温度特性
- 4.12 湿度特性
- 4.13 電源電圧の変動に対する安定性
- 4.14 外部電磁界特性
- 4.15 携帯電話と無線LANに対する電磁界特性
- 4.16 電源周波数磁界イミュニティ特性
- 4.17 静電気放電特性
- 4.18 無線周波電磁界によって誘導された伝導妨害に対するイミュニティ特性
- 4.19 こん(梱)包落下特性
- 4.20 耐微小振動特性
- 5 構造
- 5.1 構造一般
- 5.2 指示計器
- 5.3 警報
- 5.4 電源
- 5.5 測定範囲
- 6 試験
- 6.1 試験条件
- 6.2 試験方法
- 7 検査
- 7.1 一般
- 7.2 形式検査
- 7.3 受渡検査
- 8 表示
- 9 取扱説明書
- 附属書A(規定)変動係数の許容値を変更する係数の決定方法
- 附属書B(参考)統計的変動
- 附属書C(参考)サーベイメータの使用分類
- 附属書JA(参考)相対基準誤差試験
- 附属書JB(参考)エネルギー・方向特性試験での試験点の低減方法
- 附属書JC(規定)線量当量換算係数
- 附属書JD(参考)JISと対応国際規格との対比表
適用範囲 [1]
この規格は,放射線サーベイを目的として,X線,γ線とβ線の周辺線量当量(率)H*(10),H*(10)と/又は方向性線量当量(率)H‘(0.07),H'(0.07)を測定する携帯形の線量(率)計と警報付き線量(率)計(以下,サーベイメータという。)について規定する。
ただし,次に示す特別な性能については,規定しない。
- a) 放射線診断と放射線治療に用いる放射線場の線量(率)測定に関わる特別な性能。
- b) パルス放射線場の線量(率)測定に関わる特別な性能。
- c) 事故時又は緊急時の線量当量(率)測定に関わる特別な性能。
注記 この規格の対応国際規格とその対応の程度を表す記号を,次に示す。
IEC 60846-1:2009,Radiation protection instrumentation-Ambient and/or directional dose equivalent
(rate) meters and/or monitors for beta, X and gamma radiation-Part 1: Portable workplace and environmental meters and monitors(MOD)
なお,対応の程度を表す記号「MOD」は,ISO/IEC Guide 21-1に基づき,「修正している」ことを示す。
引用規格 [2]
次に掲げる規格は,この規格に引用されることによって,この規格の規定の一部を構成する。これらの引用規格のうちで,西暦年を付記してあるものは,記載の年の版を適用し,その後の改正版(追補を含む。)は適用しない。西暦年の付記がない引用規格は,その最新版(追補を含む。)を適用する。
JIS C 61000-4-2 電磁両立性-第4-2部:試験と測定技術-静電気放電イミュニティ試験
注記 対応国際規格:IEC 61000-4-2,Electromagnetic compatibility (EMC)-Part 4-2: Testing and measurement techniques-Electrostatic discharge immunity test(IDT)
JIS C 61000-4-3 電磁両立性-第4-3部:試験と測定技術-放射無線周波電磁界イミュニティ試験
注記 対応国際規格:IEC 61000-4-3,Electromagnetic compatibility (EMC)-Part 4-3: Testing and
measurement techniques-Radiated, radio-frequency, electromagnetic field immunity test(IDT)
JIS C 61000-4-6 電磁両立性-第4-6部:試験と測定技術-無線周波電磁界によって誘導する伝導妨害に対するイミュニティ
注記 対応国際規格:IEC 61000-4-6,Electromagnetic compatibility (EMC)-Part 4-6: Testing and measurement techniques-Immunity to conducted disturbances, induced by radio-frequency fields(MOD)
JIS C 61000-4-8 電磁両立性-第4部:試験と測定技術-第8節:電源周波数磁界イミュニティ試験
注記 対応国際規格:IEC 61000-4-8,Electromagnetic compatibility (EMC)-Part 4-8: Testing and measurement techniques-Power frequency magnetic field immunity test(MOD)
JIS Z 4001 原子力用語
注記 対応国際規格:IEC 60050-393,International Electrotechnical Vocabulary-Part 393: Nuclear instrumentation-Physical phenomena and basic conceptsとIEC 60050-394,International Electrotechnical Vocabulary-Part 394: Nuclear instrumentation-Instruments, systems, equipment and detectors(MOD)
JIS Z 4511 照射線量測定器,空気カーマ測定器,空気吸収線量測定器と線量当量測定器の校正方法
JIS Z 4514 β線組織吸収線量測定器と線量当量測定器の校正方法
注記 対応国際規格:ISO 6980-1,Nuclear energy-Reference beta-particle radiation-Part 1: Methods of production,ISO 6980-2,Nuclear energy-Reference beta-particle radiation-Part 2: Calibration fundamentals related to basic quantities characterizing the radiation fieldとISO 6980-3,Nuclear energy-Reference beta-particle radiation-Part 3: Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence(MOD)
JIS Z 8103 計測用語
ISO 4037-1:1996,X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 1: Radiation characteristics and production methods
ISO 4037-2:1997,X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1.3 MeV and 4 MeV to 9 MeV
ISO 4037-3:1999,X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
ISO 4037-4:2004,X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields
用語と定義 [3]
この規格で用いる主な用語と定義は,JIS Z 4001とJIS Z 8103によるほか,次による。
変動係数,ν(coefficient of variation) [3.1]
n個の測定値(xi)の標準偏差の推定値(s)の平均値(x-)に対する比をいい,次の式によって求められる。
レスポンス,R(response)
サーベイメータの指示値(G)の線量(率)の取決め真値(Ht)に対する比をいい,次の式によって求められる。
R=G/Ht
基準レスポンス,R0(reference response) [3.3]
基準となる条件下で得られたサーベイメータの指示値(Gr,0)の線量(率)の取決め真値(Hr,0)に対する比をいい,次の式によって求められる。
R0=Gr,0/Hr,0
相対レスポンス,r(relative response) [3.4]
表5に示す試験条件のうち,特定の試験条件で得られたレスポンス(R)の基準レスポンス(R0)に対する比をいい,次の式によって求められる。
r=R/R0
有効測定範囲(effective range of measurement) [3.5]
サーベイメータがこの規格の規定する性能に適合する測定範囲。
有効測定範囲の下限値,H0,H0(lower limit of effective range of measurement) [3.6]
有効測定範囲の最小の線量と線量率。
指示値,G(indicated value) [3.7]
サーベイメータの指示値。
基準の向き(reference orientation) [3.8]
放射線の入射方向に対して,基準とするサーベイメータの向きで,製造業者が指定する。
基準点(reference point) [3.9]
線量(率)測定において基準とするサーベイメータの構造上の点で,製造業者が指定する。
取決め真値,Ht,Ht(conventional true value) [3.10]
試験に用いる線量(率)の最良推定値。
相対拡張不確かさ,urel(relative expanded uncertainty) [3.11]
取決め真値の拡張不確かさの取決め真値に対する比。
定格範囲(rated range) [3.12]
サーベイメータがこの規格の規定する性能を満たす影響量1) の範囲で,少なくとも最小定格範囲を含む。
注1) 放射線のエネルギー,入射角度,環境条件などが該当する。
最小定格範囲(minimal rated range) [3.13]
この規格がサーベイメータに要求する最小限の定格範囲。
周辺線量当量,H*(10)(ambient dose equivalent) [3.14]
拡張・整列場によって作り出される放射線場に置かれたICRU球内の整列場の方向に対向する半径上の深さ10 mmの点における線量当量。
注記1 単位は,シーベルト(Sv)である。
注記2 周辺線量当量率はH*(10) で示し,単位は,シーベルト毎時(Sv/h)などである。
注記3 JIS Z 4511に規定する,場所に関わる1 cm線量当量は,H*(10) に相当する。
方向性線量当量,H'(0.07,α)(directional dose equivalent) [3.15]
拡張放射線場に置かれた,ICRU球内のある方向の半径上の深さ0.07 mmの点における線量当量。校正場を用いたサーベイメータの方向特性の評価においては,サーベイメータの基準の向きに対して角度αをなす向きからICRU球に照射した場合の,基準の向きに対向する半径上の,深さ0.07 mmの点における線量当量を示す。
注記1 単位は,シーベルト(Sv)である。
注記2 方向性線量当量率はH‘(0.07,α)で示し,単位は,シーベルト毎時(Sv/h)などである。
注記3 特定の方向とは,放射線の入射方向のことである。
注記4 入射角度α=0°のとき,H'(0.07)と示すこともある。
注記5 JIS Z 4511に規定する,場所に関わる70 μm線量当量は,H'(0.07)に相当する。
性能 [4]
直線性 [4.1]
直線性は,6.2.2によって試験したとき,相対レスポンスは0.85+urel~1.22+urelとする。
注記 4.1と6.2.2において,urelは,直線性試験での基準となる線量(率)の試験点における線量(率)に対する比の相対拡張不確かさである。
X線 関連 主なJIS規格 一覧
| 規格番号 | 規格名称 | 規格番号 | 規格名称 |
|---|---|---|---|
| JIS T 61331-3 | 診断用X線に対する防護用具-第3部:防護衣,防護眼鏡と患者用防護具 | JIS Z 3110 | 溶接継手の放射線透過試験方法-デジタル検出器によるX線とγ線撮影技術 |
| JIS Z 4102 | 医用X線管 | JIS Z 4120 | 診断用X線管装置-焦点特性 |
| JIS Z 4121 | X線管装置の固有ろ過の測定 | JIS Z 4122 | 診断用回転陽極X線管装置の最大対称照射野の決定 |
| JIS Z 4312 | X線,γ線,β線と中性子用電子式個人線量(率)計 | JIS Z 4324 | X線とγ線用据置形エリアモニタ |
| JIS Z 4333 | X線,γ線とβ線用線量当量(率)サーベイメータ | JIS Z 4344 | X線とγ線用可搬形エリアモニタ |
| JIS Z 4501 | X線防護用品類の鉛当量試験方法 | JIS Z 4511 | X線とγ線用線量(率)測定器の校正方法 |
| JIS Z 4606 | 工業用X線装置 | JIS Z 4613 | 胸部間接撮影用コンデンサ式X線装置 |
| JIS Z 4615 | 工業用X線装置の実効焦点寸法測定方法 | JIS Z 4701 | 医用X線装置通則 |
| JIS Z 4702 | 医用X線高電圧装置通則 | JIS Z 4703 | 医用X線機械装置通則 |
| JIS Z 4704 | 医用X線管装置 | JIS Z 4711 | 診断用一体形X線発生装置 |
| JIS Z 4712 | 診断用X線可動絞り | JIS Z 4713 | 暗流X線遮へい用シャッタ |
| JIS Z 4716 | X線診療室の漏えいX線量の測定方法 | JIS Z 4721 | 医用X線イメージインテンシファイア |
| JIS Z 4731 | 医用X線装置用高電圧プラグとソケット | JIS Z 4732 | 医用X線装置用プラグ付高電圧ケーブル |
| JIS Z 4751-2-28 | 医用電気機器-第2-28部:診断用X線管装置の基礎安全と基本性能に関する個別要求事項 | JIS Z 4751-2-43 | IVR用X線装置-基礎安全と基本性能 |
| JIS Z 4751-2-44 | 医用電気機器-第2-44部:X線CT装置の基礎安全と基本性能に関する個別要求事項 | JIS Z 4751-2-45 | 医用電気機器-第2-45部:乳房用X線装置と乳房撮影定位装置の基礎安全と基本性能に関する個別要求事項 |
| JIS Z 4751-2-54 | 医用電気機器-第2-54部:撮影・透視用X線装置の基礎安全と基本性能に関する個別要求事項 | JIS Z 4751-2-7 | 診断用X線高電圧装置-安全 |
| JIS Z 4752-2-10 | 医用画像部門における品質維持の評価と日常試験方法-第2-10部:不変性試験-乳房用X線装置 | JIS Z 4752-2-11 | 医用画像部門における品質維持の評価と日常試験方法-第2-11部:不変性試験-直接撮影用X線装置 |
| JIS Z 4752-2-7 | 医用画像部門における品質維持の評価と日常試験方法-第2-7部:不変性試験-口内法撮影用X線装置 | JIS Z 4752-2-8 | 医用画像部門における品質維持の評価と日常試験方法-第2-8部:不変性試験-X線防護具類 |
| JIS Z 4752-2-9 | 医用画像部門における品質維持の評価と日常試験方法-第2-9部:不変性試験-間接透視と間接撮影用X線装置 | JIS Z 4752-3-1 | 医用画像部門における品質維持の評価と日常試験方法-第3-1部:受入試験-診断用X線装置 |
| JIS Z 4752-3-3 | 医用画像部門における品質維持の評価と日常試験方法-第3-3部:受入試験-ディジタルサブトラクション血管造影(DSA)用X線装置 | JIS Z 4752-3-4 | 医用画像部門における品質維持の評価と日常試験方法-第3-4部:受入試験-歯科用X線装置の画像性能 |
| JIS Z 4752-3-5 | 医用画像部門における品質維持の評価と日常試験方法-第3-5部:受入試験-医用X線CT装置 | JIS Z 4901 | 胸部X線間接撮影用ミラーカメラ |
| JIS Z 4904 | 医用X線直接撮影台 | JIS Z 4910 | 診断用X線映像装置-汎用と乳房用散乱線除去グリッドの特性 |
| JIS Z 4912 | 医用X線増感紙の寸法 | JIS Z 4915 | 胸・腹部用X線水ファントム |
| JIS Z 4916 | X線用解像力テストチャート | JIS Z 4917 | X線変調度伝達関数測定用テストチャート |
| JIS Z 4920 | X線写真フィルム用ネームプリンタ | JIS Z 4921 | X線管電圧測定器 |
| JIS Z 4923 | X線CT装置用ファントム | JIS Z 4930 | X線骨密度測定装置用性能評価ファントム |
用語・記号、資格・認証・適合性評価、放射線透過試験、超音波探傷試験、浸透探傷試験、磁気探傷試験、渦電流探傷試験、漏れ試験、外観試験・目視観察、共通